Three Carrier-Neutral Facilities

We operate out of CoreSite's three Los Angeles data centers, including world famous One Wilshire with direct access to 300+ networks

CoreSite Los Angeles #2

Our Primary datacenter for all workloads

LA2 is our primary footprint in Los Angeles and offers great flexibility with power, cooling, networking and cabinet space. Only 1 mile away from One Wilshire, a standard cross connect of single mode fiber is available to world famous One Wilshire.

Contact us to schedule a tour of the facility.

Address: 900 North Alameda Street, Los Angeles, CA 90012

 

Large Cabinets

Our standard racks are 47u tall and 1200mm deep with key and combination locks

 

Power Options

Supporting Single and Three Phase Power from 2kW to 21kW per rack with A+B power

 

On-Site Parking

Free On-Site secure parking for guests and badge holders

 

Break & Conference Rooms

Each floor includes tech lounges, kitchens and a conference room. WiFi available throughout

Building
Space424,000 Square Feet across 5 floors
ServicesPartial Rack, Full Rack, Cages, Suites, Roof Top Available
PowerAC & DC
Layout10' Ceiling and 36" raised floors (except basement)
Cross ConnectSingle Mode Fiber to LA1, LA2 and LA3
Internet ExchangesAny2West, BBIX, NYIIX Los Angeles, MorePeering, GraniteIX, MegaIX
Compliance CertificationsSOC 1 Type 2, SOC 2 Type 2, ISO 27001, NIST 800-53, PCI DSS, HIPAA
Facilities
AccessKey cards, biometric scanners, 8' perimeter fence, mantrap and controlled site access
CamerasPerimeter, interior IP-DVR and off-site access
Security Officers24x7x365 security qualified personnel
ElevatorsPassenger: 6'6"w x 5'd x 7'6"h (6,000 lbs.)
Large Freight: 5'6"w x 16'd x 8'2"h (10,000 lbs.)
Small Freight: 5'6"w x 10'd x 8'2"h (5,000 lbs.)
Loading DockExterior 4' dock height with levelers and a lift. 53' trailer accommodation
Column Spacing28' x 28'
Efficiency
CoolingCentralized N+1 chiller system with evaporative cooling towers utilizing a water-side economizer design
ChillerVariable speed CRAHs and steam canister humidification
ElectricalHigh-efficiency UPS systems
Life SafetyDual-interlock pre-action dry-pipe sprinkler system with VESDA
Utility SafetyPower delivered from utility at high voltage to achieve rate reduction and distribution efficiencies
MonitoringRF Code and direct wire temperature and humidity sensors at each rack
Reliability
UtilitiesDiverse utility feeds from LADWP, Critical Infrastructure Site
GeneratorsN+1 redundancy. Annual pull the plug tests
Security Officers24x7x365 security qualified personnel
Operations & Remote Hands24x7x365 on-site personnel
Power SLA100%
Fuel Storage24 hours on-site storage with multiple refueling contracts
UPS/PDU/RPPN+1 redundancy
MechanicalN+1 mechanical systems
Flood PlainSystems above 500-year flood plain

CoreSite Los Angeles #1

World Famous One Wilshire

LA1 is one of the most densely interconnected data centers in the world with subsea, dark fiber and regional providers terminating all connections in this building. CoreSite operates the meet-me-room and is the largest tenant in this building.

Hosting services here are typically reserved for customers who are latency sensitive when peering with other networks.

Address: 624 South Grand Avenue, Los Angeles, CA 90017

 

Partial Cabinets Available

We can accommodate partial cabinet customers looking to setup a point of presence at One Wilshire

Building
Space173,000 Square Feet across multiple floors
ServicesPartial Rack, Full Rack, Cages, Suites, Roof Top Available
PowerAC & DC
Layout12' 8.5" above solid floor (no raise floors)
Building enforced weight limit, per rack tile.
Cross ConnectSingle Mode Fiber to LA1, LA2 and LA3
Internet ExchangesAny2West, BBIX, NYIIX Los Angeles, MorePeering, GraniteIX, MegaIX
Compliance CertificationsSOC 1 Type 2, SOC 2 Type 2, ISO 27001, NIST 800-53, PCI DSS, HIPAA
Facilities
AccessKey cards, biometric scanners, 8' perimeter fence, mantrap and controlled site access
CamerasPerimeter, interior IP-DVR and off-site access
Security Officers24x7x365 security qualified personnel
Elevators9 Passenger: 6'1"w x 4'9"d x 7'8"h (2,500 lbs.)
2 Freight: 6'1"w x 4'9"d x 8'4"h (3,000 lbs.)
Loading DockCovered loading dock
Column Spacing30' x 30'
Efficiency
CoolingCondenser water
ChillerN+1 cooling towers and cooling pumps
ElectricalHigh-efficiency UPS systems
Life SafetyDual-interlock pre-action dry-pipe sprinkler system with VESDA
Utility SafetyPower delivered from utility at high voltage to achieve rate reduction and distribution efficiencies
MonitoringRF Code and direct wire temperature and humidity sensors at each rack
Reliability
UtilitiesDiverse utility feeds from LADWP, Critical Infrastructure Site
GeneratorsN+1 redundancy. Annual pull the plug tests
Security Officers24x7x365 security qualified personnel
Operations & Remote Hands24x7x365 on-site personnel
Power SLA100%
Fuel Storage24 hours on-site storage with multiple refueling contracts
UPS/PDU/RPPN+1 redundancy
MechanicalN+1 mechanical systems
Flood PlainSystems above 500-year flood plain

CoreSite Los Angeles #3

Nvidia DGX-Ready Data Center

One of the few purpose built datacenters in Los Angeles, CoreSite's LA #3 datacenter is designed for high density colocation. Supports water cooling and demanding power needs for artificial intelligence (AI) and machine learning (ML). One of the first data centers in Los Angeles to reach Nvidia DGX & GPU ready certifications.

Standard single mode fiber cross connect available to One Wilshire and CoreSite LA #2.

Address: 200 Bauchet Street, Los Angeles, CA 90012

 

Large Cabinets

Our standard racks are 47u tall and 1200mm deep with key and combination locks

 

18 Megawatts

Supports up to 18 megawatts of power across the datacenter

 

On-Site Parking

Free On-Site secure parking for guests and badge holders

 

Break & Conference Rooms

Each floor includes tech lounges, kitchens and a conference room. WiFi available throughout

Building
Space160,000 Square Feet across multiple floors
ServicesFull Rack, Cages, Suites, Roof Top Available
PowerAC & DC
Layout11' above with 36" raised floors
Cross ConnectSingle Mode Fiber to LA1, LA2 and LA3
Internet ExchangesAny2West, BBIX, NYIIX Los Angeles, MorePeering, GraniteIX, MegaIX
Compliance CertificationsSOC 1 Type 2, SOC 2 Type 2, ISO 27001, NIST 800-53, PCI DSS, HIPAA
Facilities
AccessKey cards, biometric scanners, 8' perimeter fence, mantrap and controlled site access
CamerasPerimeter, interior IP-DVR and off-site access
Security Officers24x7x365 security qualified personnel
Elevators1 Passenger: Load Capacity: 5000 lbs.
Doorway Dimensions: 53" wide x 107" height
Interior Dimensions: 74" wide x 113" height x 12'-3" deep
1 Freight: Load Capacity: 10,000 lbs.
Doorway Dimensions: 67" wide x 107" height
Interior Dimensions: 74" wide x 113" height x 12'-3" deep
Loading DockCovered loading dock
Column Spacing29' x 30'
Efficiency
CoolingVariable speed fans for optimal effi ciency
ChillerSelf-contained rooftop AC units with integrated dehumidifi cation system and air-side economization
ElectricalHigh-efficiency UPS systems
Life SafetyDual-interlock pre-action dry-pipe sprinkler system with VESDA
Utility PowerPower taken at 12kV to achieve rate reduction and distribution efficiencies
Utility SafetyPower delivered from utility at high voltage to achieve rate reduction and distribution efficiencies
MonitoringRF Code and direct wire temperature and humidity sensors at each rack
Reliability
UtilitiesDiverse utility feeds from LADWP, Critical Infrastructure Site
GeneratorsN+1 redundancy. Annual pull the plug tests
Security Officers24x7x365 security qualified personnel
Operations & Remote Hands24x7x365 on-site personnel
Power SLA100%
Fuel Storage24 hours on-site storage with multiple refueling contracts
UPS/PDU/RPPN+1 redundancy
MechanicalN+1 mechanical systems
Flood PlainSystems above 500-year flood plain